Specifications
infotip-icon
View other Control Relays dimensions or variations
Please select at least one specification below.
Utilisation Category
AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 DC-14 conforming to IEC 60947-5-1
Standards
IEC 60255-6
[Ui] Rated Insulation Voltage
250 V conforming to IEC 60664-1 400 V conforming to IEC 60664-1
Mounting Support
35 mm symmetrical DIN rail conforming to IEC 60715
Ip Degree Of Protection
IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529
Ambient Air Temperature For Operation
-20…50 °C
Mechanical Durability
30000000 cycles
Ambient Air Temperature For Storage
-40…70 °C
Minimum Switching Current
10 mA at 5 V DC
Insulation Resistance
> 500 MOhm at 500 V DC conforming to IEC 60255-5 > 500 MOhm at 500 V DC conforming to IEC 60664-1
Product Certifications
UL GL GOST C-Tick CSA
Connections - Terminals
Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...2 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
This spec is not available in the specification table.
Tightening Torque
0.6…1 N.m conforming to IEC 60947-1
This spec is not available in the specification table.
Immunity To Microbreaks
20 ms
This spec is not available in the specification table.
Local Signalling
LED (green) for power ON LED (yellow) for relay ON
This spec is not available in the specification table.
Control Type
Without test button
This spec is not available in the specification table.
Range Of Product
Harmony Control Relays
This spec is not available in the specification table.
Housing Material
Self-extinguishing plastic
This spec is not available in the specification table.
Overvoltage Category
III conforming to IEC 60664-1
This spec is not available in the specification table.
Pollution Degree
3 conforming to IEC 60664-1
This spec is not available in the specification table.
Relative Humidity
95 % at 55 °C conforming to IEC 60068-2-30
This spec is not available in the specification table.
Electrical Durability
100000 cycles
This spec is not available in the specification table.
Electromagnetic Compatibility
Emission standard for industrial environments conforming to IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 Immunity for industrial environments conforming to NF EN/IEC 61000-6-2
This spec is not available in the specification table.
Contacts Type And Composition
1 C/O
This spec is not available in the specification table.
Shock Resistance
5 gn conforming to IEC 60068-2-27
This spec is not available in the specification table.
Vibration Resistance
0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6 1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1
This spec is not available in the specification table.
Supply Voltage Limits
50…270 V AC/DC
This spec is not available in the specification table.
Directives
73/23/EEC - low voltage directive 89/336/EEC - electromagnetic compatibility
This spec is not available in the specification table.
Maximum Power Consumption In W
1 W DC
This spec is not available in the specification table.
Power Consumption In Va
0…3 VA AC
This spec is not available in the specification table.
Maximum Switching Current
5 A AC/DC
This spec is not available in the specification table.
Maximum Switching Voltage
250 V AC/DC
This spec is not available in the specification table.
Operating Rate
<= 360 operations/hour full load
This spec is not available in the specification table.
Safety Reliability Data
B10d = 470000 MTTFd = 502.2 years
This spec is not available in the specification table.
Nominal Output Current
5 A
This spec is not available in the specification table.
Repeat Accuracy
+/- 0.5 % for input and measurement circuit +/- 1 % for time delay
This spec is not available in the specification table.
Switching Capacity In Va
1250 VA
This spec is not available in the specification table.
Relay Type
Voltage control relay
This spec is not available in the specification table.
Relay Name
RM17UBE
This spec is not available in the specification table.
Relay Monitored Parameters
Self-powered Overvoltage and undervoltage detection
This spec is not available in the specification table.
Time Delay
Adjustable 0.1...10 s, 0 + 10 % Tt- time delay upon fault
This spec is not available in the specification table.
Measurement Range
65...260 V AC/DC
This spec is not available in the specification table.
Reset Time
1500 ms time delay
This spec is not available in the specification table.
Output Contacts
1 C/O
This spec is not available in the specification table.
Hysteresis
3 % fixed of threshold setting
This spec is not available in the specification table.
Delay At Power Up
1000 ms DC 500 ms AC
This spec is not available in the specification table.
Maximum Measuring Cycle
150 ms measurement cycle as true rms value
This spec is not available in the specification table.
Measurement Error
< 1 % over the whole range with voltage variation 0.2 %/°C with temperature variation
This spec is not available in the specification table.
[Un] Rated Nominal Voltage
, self-powered
This spec is not available in the specification table.
Dielectric Test Voltage
2 kV, 1 min AC 50 Hz conforming to IEC 60255-5 2 kV, 1 min AC 50 Hz conforming to IEC 60664-1
This spec is not available in the specification table.
Product Description
S$ 210.70
(exc. GST)
S$ 229.66
(inc. GST)
Quantity:
/ EA
This item is sold by
Image
Schneider Electric
Shop by Specification Table
You can find items with similar specifications from the table below.
Control Relays
37 Items
control-relays-img
Utilisation Category
AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 DC-14 conforming to IEC 60947-5-1, AC-14 AC-15 DC-13, AC-14 DC-13 AC-15, AC-15 AC-14 DC-13
Standards
EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1, EN/IEC 60947-5-1 GB/T 14048.5 UL 60947-5-1 CSA C22.2 No 60947-5-1 JIS C8201-5-1, EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1, IEC 60255-1, IEC 60255-6
[Ui] Rated Insulation Voltage
250 V conforming to IEC 60664-1, 250 V conforming to IEC 60664-1 400 V conforming to IEC 60664-1, 400 V, 600 V UL certified 600 V CSA certified 690 V conforming to IEC 60947-5-1
Mounting Support
35 mm DIN rail conforming to IEC 60715, 35 mm symmetrical DIN rail conforming to IEC 60715, Plate Rail, Rail Plate
Ip Degree Of Protection
IP20 conforming to IEC 60529, IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529, IP20 (terminals) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 IP40 (front panel) conforming to IEC 60529, IP20 (terminals) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529
Ambient Air Temperature For Operation
-20…50 °C, -20…50 °C at 60 Hz -20…60 °C at 50 Hz, -20…50 °C at 60 Hz -20…60 °C at 50 Hz AC/DC, -20…60 °C
Mechanical Durability
10000000 cycles, 10 Mcycles, 20 Mcycles, 30000000 cycles
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Control Relays from SCHNEIDER ELECTRIC
Source & compare similar products
More from Control Relays
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top