Shopping List
Shopping List
SGD - S$
Image
/
/
/
/
Schneider Electric METSEPM3255 2 Digital I - PM3255 Power Meter
Schneider Electric METSEPM3255 2 Digital I - PM3255 Power Meter
Image
Image
Specifications
infotip-icon
View other Power & Energy Meters dimensions or variations
Please select at least one specification below.
Range
PowerLogic
[In] Rated Current
5 A 1 A
Type of Measurement
Active and reactive power Apparent power Current Voltage Energy Power factor Frequency Total current harmonic distortion THD (I) Total voltage harmonic distortion THD (U)
Display Type
Backlit LCD
Standards
BS EN 61557-12 IEC 61557-12 EN 61557-12 BS EN 61326-1 IEC 61326-1 EN 61326-1 BS EN 62052-11 IEC 62052-11 EN 62052-11 BS EN 62053-21 IEC 62053-21 EN 62053-21 BS EN 62053-22 IEC 62053-22 EN 62052-22 BS EN 62053-23 IEC 62053-23 EN 62052-23 BS EN 61010-1 EN 61010-1 IEC 61010-1 UL 61010-1 BS EN 61010-2-30 IEC 61010-2-30 EN 61010-2-30 UL 61010-2-30 ANSI C12.20
Ambient Air Temperature for Operation
-25…70 °C
Width
90 mm
This spec is not available in the specification table.
Device Short Name
PM3255
This spec is not available in the specification table.
Product or Component Type
Power meter
This spec is not available in the specification table.
Product Name
PowerLogic PM3000
This spec is not available in the specification table.
Depth
70 mm
This spec is not available in the specification table.
Device Application
Multi-tariff Power monitoring Sub billing
This spec is not available in the specification table.
Mounting Support
DIN rail
This spec is not available in the specification table.
Height
95 mm
This spec is not available in the specification table.
Mounting Mode
Clip-on
This spec is not available in the specification table.
Accuracy class
Class 0.5S active energy conforming to IEC 62053-22 Class 1 active energy conforming to IEC 62053-21 Class 2 reactive energy conforming to IEC 62053-23 Class C active energy conforming to EN 50470-3
This spec is not available in the specification table.
Network Frequency
60 Hz 50 Hz
This spec is not available in the specification table.
Sampling rate
32 samples/cycle
This spec is not available in the specification table.
Measurement current
0.02…1.2 A 0.05…6 A
This spec is not available in the specification table.
Communication Port Protocol
Modbus at 9.6...38.4 kbauds
This spec is not available in the specification table.
Communication port support
RS485
This spec is not available in the specification table.
Number of inputs
2 digital 0...4 mA 11...40 V DC
This spec is not available in the specification table.
Number of outputs
2 digital (static)
This spec is not available in the specification table.
Overvoltage Category
III
This spec is not available in the specification table.
Product certifications
CE conforming to IEC 61010-1 (safety) CE conforming to EN 61557-12 (power monitor) CE conforming to EN/IEC 61326-1 (EMC) UKCA conforming to BS EN 61010-1 (safety) UKCA conforming to BS EN 61557-12 (power monitor) UKCA conforming to BS EN 61326-1 (EMC) CULus conforming to EN 61010-1 (safety) CULus conforming to UL 61010-1 (safety) EAC (sub-meter) RCM
This spec is not available in the specification table.
IP Degree of Protection
IP40 front panel: conforming to IEC 60529 IP20 body: conforming to IEC 60529
This spec is not available in the specification table.
Pollution Degree
2
This spec is not available in the specification table.
Relative Humidity
5…95 % at 50 °C
This spec is not available in the specification table.
Ambient Air Temperature for Storage
-40…85 °C
This spec is not available in the specification table.
Operating Altitude
< 3000 m
This spec is not available in the specification table.
Power quality analysis
up to the 15th harmonic
This spec is not available in the specification table.
supply voltage
100...277 V AC 45...65 Hz 173...480 V AC 45...65 Hz 100...300 V DC
This spec is not available in the specification table.
type of network
3P 3P + N 1P + N
This spec is not available in the specification table.
Display resolution
128 x 96 pixels
This spec is not available in the specification table.
Analogue input type
Current 0...5 A Current 0...1 A
This spec is not available in the specification table.
Measurement voltage
50…330 V AC 45...65 Hz direct 50…330 V AC 45...65 Hz phase to neutral 80…570 V AC 45...65 Hz direct 80…570 V AC 45...65 Hz phase to phase 570…999000 V AC 45...65 Hz with external VT
This spec is not available in the specification table.
Frequency measurement range
45…65 Hz
This spec is not available in the specification table.
Measurement accuracy
Current 0.3 % 0.5...6 A Current 0.5 % 0.1...1.2 A Voltage 0.3 % 50...330 V Voltage 0.3 % 80...570 V
This spec is not available in the specification table.
data recording
Energy consumption logs 15 alarms Power logs Time stamping Min/max of instantaneous values
This spec is not available in the specification table.
Electromagnetic Compatibility
Electrostatic discharge level 4 conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 Surge immunity test level 4 conforming to IEC 61000-4-5 Conducted RF disturbances level 3 conforming to IEC 61000-4-6 Magnetic field at power frequency - test level: 0.5 mT conforming to IEC 61000-4-8 Conducted and radiated emissions class B conforming to EN 55022
This spec is not available in the specification table.
Information displayed
Tariff (4)
This spec is not available in the specification table.
memory capacity
512 KB
This spec is not available in the specification table.
Power consumption in VA
5 VA
This spec is not available in the specification table.
Product Description
S$ 1,016.50
(exc. GST)
S$ 1,107.99
(inc. GST)
Quantity:
/ EA
This item is sold by
Image
Schneider Electric
Shop by Specification Table
You can find items with similar specifications from the table below.
Power & Energy Meters
38 Items
power-energy-meters-img
Range
Acti9, EasyLogic, PowerLogic
Poles Description
1P + N, 1P + N 3P 3P + N, 3P 1P + N 3P + N, 3P 3P + N 1P + N
[In] Rated Current
125 A, 1 A 5 A, 1 A 5 A 10 A, 45 A
Type of Measurement
Active and reactive energy Active and reactive power Current Voltage, Active and reactive energy Active and reactive power Power factor Current Voltage Frequency Apparent power, Active and reactive power Apparent power Current Voltage Energy Power factor Frequency Total current harmonic distortion THD (I) Total voltage harmonic distortion THD (U), Active energy
Rated Voltage
100…277 V 173…480 V, 230 V - 15...10 %, 230 V +/- 20 %
Display Type
7 segments LED, Backlit LCD, Colour TFT LCD, Digital Display
Standards
BS EN 61557-12:2021 IEC 61557-12:2021 EN 61557-12:2021 BS EN 61326-1 IEC 61326-1 EN 61326-1 BS EN 62052-11:2020 IEC 62052-11:2020 EN 62052-11:2020 BS EN 62053-21 IEC 62053-21 EN 62053-21 BS EN 62052-22 IEC 62053-22:2020 EN 62052-22 BS EN 62052-23 IEC 62053-23:2020 EN 62052-23 BS EN 62052-31:2015 IEC 62052-31:2015 EN 62052-31:2015 BS EN 61010-1:2010 EN 61010-1:2010 IEC 61010-1:2010 UL 61010-1:2010 BS EN 61010-2-30 IEC 61010-2-30 EN 61010-2-30 UL 61010-2-30 BS EN 50470-3 EN 50470-3 BS EN 50470-1 EN 50470-1 ANSI C12.20, BS EN 61557-12:2021 IEC 61557-12:2021 EN 61557-12:2021 BS EN 61326-1 IEC 61326-1 EN 61326-1 BS EN 62052-11:2020 IEC 62052-11:2020 EN 62052-11:2020 BS EN 62053-21 IEC 62053-21 EN 62053-21 BS EN 62052-23 IEC 62053-23:2020 EN 62052-23 BS EN 62052-31:2015 IEC 62052-31:2015 EN 62052-31:2015 BS EN 61010-1:2010 EN 61010-1:2010 IEC 61010-1:2010 UL 61010-1:2010 BS EN 61010-2-30 IEC 61010-2-30 EN 61010-2-30 UL 61010-2-30 BS EN 50470-3 EN 50470-3 BS EN 50470-1 EN 50470-1 ANSI C12.16, BS EN 61557-12:2021 IEC 61557-12:2021 EN 61557-12:2021 BS EN 61326-1 IEC 61326-1 EN 61326-1 BS EN 62052-11:2020 IEC 62052-11:2020 EN 62052-11:2020 BS EN 62053-21 IEC 62053-21 EN 62053-21 BS EN 62052-31:2015 IEC 62052-31:2015 EN 62052-31:2015 BS EN 61010-1:2010 EN 61010-1:2010 IEC 61010-1:2010 UL 61010-1:2010 BS EN 61010-2-30 IEC 61010-2-30 EN 61010-2-30 UL 61010-2-30 ANSI C12.16, BS EN 61557-12:2021 IEC 61557-12:2021 EN 61557-12:2021 BS EN 61326-1 IEC 61326-1 EN 61326-1 BS EN 62052-11:2020 IEC 62052-11:2020 EN 62052-11:2020 BS EN 62053-21 IEC 62053-21 EN 62053-21 BS EN 62053-22:2020 IEC 62053-22:2020 EN 62052-22 BS EN 62052-31:2015 IEC 62052-31:2015 EN 62052-31:2015 BS EN 61010-1:2010 EN 61010-1:2010 IEC 61010-1:2010 UL 61010-1:2010 BS EN 61010-2-30 IEC 61010-2-30 EN 61010-2-30 UL 61010-2-30 ANSI C12.20
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Power & Energy Meters from SCHNEIDER ELECTRIC
Source & compare similar products
More from Power & Energy Meters
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top